1022A screw Fracture?
source:King-Tower Author:1 views:24 Release time:2014-10-27
1. hydrogen embrittlement fracture: If the C1022 material, usually carburizing heat treatment, surface hardness is relatively high, the core hardness is relatively low. The problem may be heat-treated, high hardness of the core, resulting in increased brittleness; Electroplating even do dehydroepiandrosterone treatment, but the risk of hydrogen embrittlement is still very large.
2.groove depth darker head and neck junction leading to vulnerability: the feeling that reason is not great.
3.head and neck angle is too small joint R: Like the second are the result of joint fragile.
Generally good control of these three aspects, this screw using it without any problems.